Safety News: Week of November 16

Bridge reinforcing steel and crane at a construction site — weekly safety news update

This week: a scaffold collapse under a Long Island bridge killed one worker and left another missing, Maine cited seven fire departments after a fatal mill explosion, and the Chemical Safety Board delivered two chemical-safety lessons.

Scaffold collapse under a Long Island bridge leaves one dead, one missing

Shortly before noon on Wednesday, November 11, scaffolding under the Loop Parkway drawbridge at Point Lookout, New York, gave way while eight contract workers were repairing and repainting the bridge, sending two men into the water. Kleiton De Madeiros, 39, of Montclair, New Jersey, was pulled from the water and died at a hospital, and Diogo De Oliveira, 38, of Elizabeth, New Jersey, was still missing as of Friday, November 13. The other six were hurt but not seriously. The crew worked for Champion Painting; State Police are investigating, a fire marshal said OSHA would investigate as well, and no cause has been announced. Scaffolds over water need the same discipline as any scaffold: a competent person inspects the platform before each shift, and the rescue plan must cover the water below, not just the fall. If your crew builds or works from scaffolds, take a look at our Scaffolding Safely (OSHA) training. The Journal News identified the two workers and reported the search.

Seven Maine fire departments cited after a fatal mill explosion

Maine’s labor department cited six fire departments and one rescue department after the May 15, 2026, explosion at Robbins Lumber in Searsmont killed Morrill firefighter Andrew Cross; Assistant Chief Wayne Woodbury and mill co-owner Alden Robbins later died of their injuries, and 13 more were hurt. All six fire departments received willful-serious citations for failing to use an accountability system before the silo exploded. Searsmont Fire drew a second willful-serious citation over protective equipment, and the rescue department was cited for placing its rehab area less than 50 feet from the fire’s origin, inside the collapse zone. Settlements suspended nearly all of it: Searsmont’s full $20,000, Morrill’s full $26,000, and $19,000 of Montville’s $20,000, with $1,000 due November 30, and in exchange the departments must correct the problems, train their people, and send chiefs and officers to a February 2027 workshop. At any emergency scene, knowing exactly who is inside — including mutual-aid arrivals — is the first control, and it has to work before the worst happens. Fire Law Blog covered the citations and the settlements in detail.

Chemical Safety Board: shut off a release from a safe distance

On November 12, the Chemical Safety Board released a new safety video, “RIPE for Change,” based on its 2024 study of remote isolation. The video revisits three 2019 incidents where the consequences grew worse because workers could not stop the flow of hazardous material from a safe place: a March fire at Intercontinental Terminals in Deer Park, Texas; June fire and explosions at Philadelphia Energy Solutions; and November fire and explosions at TPC Group in Port Neches, Texas. In all three, fires burned for days — one for more than a month — because the plants relied on manual valves crews could not reach safely. The board recommends that the American Petroleum Institute, the Environmental Protection Agency, and OSHA require remote isolation where it fits, and its chair, Steve Owens, urged facilities to install it before any rule requires it. The practical check is simple: if stopping a release means walking into the hazard, that valve is not a control. The Chemical Safety Board announced the video and described the three incidents behind it.

Five safety recommendations, three years of silence, one guilty plea

Five years after an explosion at the OPC Polymers resin plant in Columbus, Ohio, killed one worker and injured eight others, the Chemical Safety Board says the company never answered its five safety recommendations from November 2023. The board found that a replacement cover on a vessel called Kettle 3 was never properly designed, built, or tested, leaked soon after installation, and stayed in service until pressure forced flammable vapors through the seal on April 8, 2021. Gas detectors registered the danger without sounding an audible warning, and workers had no flame-resistant uniforms or adequate emergency training. On September 1, 2026, Yenkin-Majestic pleaded guilty to negligent endangerment under the Clean Air Act, and OSHA had already proposed $709,960 in penalties in October 2021 for two willful and 33 serious violations, though that case is still not final. The company dissolved in August 2026 and the plant has been demolished; the board now looks to OPC Polymers, which it says has not answered repeated letters since December 2023 or shown proof the fixes were made. A written chemical safety program only protects anyone if it is actually followed — if yours needs a rebuild, our federal Hazard Communication program template is a place to start. Bureaucracy Times reported the unanswered recommendations, the guilty plea, and the company’s dissolution.

Need help turning any of this into training or a written program for your crew? Contact us through 1stamericansafety.com.

Sources: The Journal News identified the workers in the Loop Parkway collapse. Fire Law Blog covered the Maine citations and settlements. The Chemical Safety Board announced its remote-isolation video. Bureaucracy Times reported the unanswered Yenkin-Majestic recommendations and the guilty plea.